HAZARDS OF PETROLEUM




                                               3
      ---ใช้เพื่อการศึกษาเท่านั้น---
                                                                            1Infra-red source
                                                                            2Window
                                                                            3 Mirror
                                                                            4Window
               งานห้องสมุด ศูนย์ฝกพาณิชย์นาวี
                                                                            5 Beam splitter
                                                                                                     r
                                                                            7 Measuring detector
                                                                            8 Reference filter
                                                                            9 Reference detector




                                                                             4


                                  2
                                                                                         8

                                                                                         9






                                                                          ึ              6
                                  1





                                                     5                 7




                                                      Figure 2.2 – Infra-red sensor



                           2.4.7 Measurement of Low Concentrations of Toxic Gases

                              2.4.7.1 Chemical Indicator Tubes

                                        Probably the most convenient and suitable equipment for measuring very
                                        low concentrations of toxic gases on board tankers are chemical indicator
                                        tubes.

                                          Measurement errors may occur if several gases are present at the
                                          same time, as one gas can interfere with the measurement of
                                          another. The instrument manufacturer’s operating instructions
                                          should always be consulted prior to testing such atmospheres.



                                        Chemical indicator tubes consist of a sealed glass tube containing a
                                        proprietary filling which is designed to react with a specific gas and to
                                        give a visible indication of the concentration of that gas. To use the
                                        device, the seals at each end of the glass tube are broken, the tube is
                                        inserted in a bellows-type fixed volume displacement hand pump, and a
                                        prescribed volume of gas mixture is drawn through the tube at a rate
                                        fixed by the rate of expansion of the bellows. A colour change occurs